Many users will not operate the machine after purchasing the ultrasonic vibrating screen, the use instructions are easy to lose, resulting in the situation that the equipment can not be used. The following Dahan Machinery Technology Department sorted out the nine-step operation method of the ultrasonic vibrating screen for you. If you still can’t operate after reading, you can also click on customer service or dial the telephone to consult online. Dahan Vibration Machinery Company is very happy to serve you.~
Operating Method of Ultrasound Vibrating Screen
1. Ultrasound system should use the whole set of testing, many customers reflect that the ultrasonic system can not be used normally after overhaul. The reason is that if there is no problem after power box anti-factory testing, but the transducer has not been inspected, resulting in transducer failure, only the power box can be overhauled according to the failure to find any problems.
2. The working power supply and voltage of the ultrasonic system are 220V. The output power of the ultrasonic system is connected to the transducer by the data wire drawn from the back panel of the power box. The red is the positive pole. When connecting, special attention should be paid to the voltage pole term, so that no mistake can be made.
3. When the screening effect can be achieved, the power shield should be lowered as far as possible, and the maximum current should not exceed 0.4. Unnecessary energy consumption and unnecessary damage of power supply overcurrent should be avoided.
4. Don’t turn on the ultrasonic system when the mesh screen is not stretched. Otherwise, the transducer will be damaged because of the over-current of the power supply.
5. Screening screen tension can achieve the best screening effect, otherwise it will produce ultrasound output and vibration effect, seriously affecting the screening effect and screening output.
6. The aviation plug screw on the transducer must be tightened, and the data wire must be checked regularly for damage. The aviation joint and data wire must be wrapped with insulating tape to prevent dust. If the air plug is not tightened, the vibration wave energy of the ultrasonic vibration screen can not be transmitted. It loses its vibration effect.
7. If the material has conductivity, please keep the power box away from the material site, so as to prevent the material from entering the power box and causing short circuit.
8. If you find that the noise in the power supply is too big or the fan can’t move, please stop working immediately and check the heat dissipation fan. Please pay attention to ventilation when using power box.
9. Each set of ultrasound includes a resonant power supply, an oscillator and a grid. Number matching is better for the three, and do not mix with other ultrasonic dishes.