In order to make the laser welding machine work better, reduce the number of breakdowns, increase work efficiency, we must understand the operation process should pay attention to the problems and troubleshooting methods. Below by the manufacturer Jin silk square laser technician for everyone to analyze the top cover laser welding machine common fault treatment methods.
1. Abnormal stop of the laser welding equipment of the cover pre-welding: check the alarm screen related to the alarm, there is an alarm that the equipment will automatically switch to the pause state and the reset button will flicker at the frequency of 0.2s. At the same time, the buzzer will call at the frequency of 1s and the red light of the three-color lamp will always be on, to solve the relevant alarm and press the alarm again. The bit button can reset the alarm and press the start button to continue running.
2. When the laser welding is wrong, press the emergency stop button in time, the system will automatically cut off the laser control, the servo motor power supply, to prevent accidents, emergency stop after the bomb must be initialized;
3. When the equipment of laser welding machine is not working, please check whether the touch screen alarm or the equipment is suspended or waiting for material.
The whole machine reset alarm: it is necessary to reset the top cover pre welding laser welding machine to run the whole machine.
4. Limit alarm: it shows that the motor reaches the soft limit and can only run in the opposite direction without reset.
5. Shaft ALM alarm: simply return the alarm to the reset axis or press the reset button in the function window.
6. When the laser is out of control, it is necessary to press the stop button quickly, stop sending laser signal and break down the welding shaft. After dealing with the snap stop button, the cover pre-welding laser welding machine can be reset and run again.
7. Note: several minutes of the top cover pre welding laser welding machine.
The welding will stop automatically for one minute after stopping and blow nitrogen.
When an alarm occurs, the beep will be repeated after one minute.
Online body feed will last for only one minute, only 1PCS will automatically feed.
After the failure, we can refer to the above contents for operation inspection.